新聞資訊
News
1
應先(xian)檢測周圍(wei)環(huan)境的(de)溫度(du)及濕(shi)度(du),溫度(du)過高會(hui)(hui)導致變(bian)(bian)(bian)(bian)(bian)頻器(qi)(qi)(qi)(qi)過熱報警,嚴重時會(hui)(hui)直接導致變(bian)(bian)(bian)(bian)(bian)頻器(qi)(qi)(qi)(qi)功(gong)率(lv)器(qi)(qi)(qi)(qi)件損壞、電(dian)路(lu)短路(lu);空氣過于潮濕(shi)會(hui)(hui)導致變(bian)(bian)(bian)(bian)(bian)頻器(qi)(qi)(qi)(qi)內部(bu)直接短路(lu)。在(zai)變(bian)(bian)(bian)(bian)(bian)頻器(qi)(qi)(qi)(qi)運行(xing)時要注(zhu)意其冷(leng)卻系(xi)統是(shi)否(fou)(fou)正(zheng)產,如(ru):風(feng)道排(pai)(pai)風(feng)是(shi)否(fou)(fou)流(liu)暢,風(feng)機是(shi)否(fou)(fou)有(you)異(yi)常聲(sheng)音。一般防護等(deng)級(ji)比(bi)較高的(de)變(bian)(bian)(bian)(bian)(bian)頻器(qi)(qi)(qi)(qi)如(ru):IP20以上的(de)變(bian)(bian)(bian)(bian)(bian)頻器(qi)(qi)(qi)(qi)可直接敞開(kai)安裝,IP20以下(xia)的(de)變(bian)(bian)(bian)(bian)(bian)頻器(qi)(qi)(qi)(qi)一般應是(shi)柜(ju)式(shi)安裝,所(suo)以變(bian)(bian)(bian)(bian)(bian)頻柜(ju)散熱效果如(ru)何(he)將直接影響變(bian)(bian)(bian)(bian)(bian)頻器(qi)(qi)(qi)(qi)的(de)正(zheng)常運行(xing),變(bian)(bian)(bian)(bian)(bian)頻器(qi)(qi)(qi)(qi)的(de)排(pai)(pai)風(feng)系(xi)統如(ru)風(feng)扇旋轉是(shi)否(fou)(fou)流(liu)暢,進(jin)風(feng)口是(shi)否(fou)(fou)有(you)灰塵及阻塞物都是(shi)我們日(ri)常檢查(cha)不可忽略的(de)地方(fang)。電(dian)動(dong)機電(dian)抗器(qi)(qi)(qi)(qi)、變(bian)(bian)(bian)(bian)(bian)壓器(qi)(qi)(qi)(qi)等(deng)是(shi)否(fou)(fou)過熱,有(you)異(yi)味;變(bian)(bian)(bian)(bian)(bian)頻器(qi)(qi)(qi)(qi)及馬達是(shi)否(fou)(fou)有(you)異(yi)常響聲(sheng);變(bian)(bian)(bian)(bian)(bian)頻器(qi)(qi)(qi)(qi)面板(ban)電(dian)流(liu)顯示是(shi)否(fou)(fou)偏大(da)或電(dian)流(liu)變(bian)(bian)(bian)(bian)(bian)化幅度(du)太大(da),輸出UVW三相電(dian)壓與電(dian)流(liu)是(shi)否(fou)(fou)平衡等(deng)。
2
定期保養定(ding)期除(chu)塵檢查風(feng)扇進風(feng)口(kou)是否(fou)堵死,每月清(qing)掃空氣過濾器冷卻風(feng)道及內部灰塵。
定期檢查,應一年進行一次:檢查螺絲(si)釘(ding)、螺栓以及(ji)即插件等是(shi)(shi)否松動,輸(shu)入輸(shu)出電(dian)(dian)抗(kang)器(qi)的(de)對(dui)地及(ji)相(xiang)間電(dian)(dian)阻是(shi)(shi)否有(you)短(duan)路(lu)現象,正(zheng)常(chang)(chang)應大于幾(ji)十(shi)兆歐。導體及(ji)絕緣體是(shi)(shi)否有(you)腐蝕現象,如(ru)有(you)要及(ji)時用酒(jiu)精擦(ca)拭干凈。測量(liang)開關電(dian)(dian)源輸(shu)出各電(dian)(dian)路(lu)電(dian)(dian)壓(ya)的(de)平(ping)穩(wen)性,如(ru):5V、12V、15V、24V等電(dian)(dian)壓(ya)。接觸器(qi)的(de)觸點(dian)是(shi)(shi)否有(you)打火痕跡,嚴重的(de)要更(geng)換(huan)同型號或大于原(yuan)容量(liang)的(de)新品(pin)接觸器(qi);確(que)認控制(zhi)電(dian)(dian)壓(ya)的(de)正(zheng)確(que)性,進行順(shun)序保(bao)護動作試驗;確(que)認保(bao)護顯示回路(lu)無異常(chang)(chang);確(que)認變頻器(qi)在單獨運行時輸(shu)出電(dian)(dian)壓(ya)的(de)平(ping)衡度(du)。
認真(zhen)做好變(bian)頻器的日常維護保養及(ji)其檢修工(gong)作(zuo),內容主要(yao)包括:
(1)定期(qi)對變(bian)(bian)頻器進(jin)行除塵(chen)(chen),重點是整流柜(ju)、逆變(bian)(bian)柜(ju)和控(kong)制柜(ju),必要時可將(jiang)整流模(mo)塊(kuai)、逆變(bian)(bian)模(mo)塊(kuai)和控(kong)制柜(ju)內的(de)線路板拆出后進(jin)行除塵(chen)(chen)。變(bian)(bian)頻器下進(jin)風(feng)口、上出風(feng)口是否積(ji)塵(chen)(chen)或(huo)因積(ji)塵(chen)(chen)過(guo)多(duo)而堵塞。變(bian)(bian)頻器因本身散(san)熱要求通風(feng)量(liang)大,故運行一定時間以后,表面積(ji)塵(chen)(chen)十分嚴重,須(xu)定期(qi)清潔(jie)除塵(chen)(chen)。
(2)將變頻器前(qian)門打(da)開(kai), 后門拆開(kai), 仔細檢查交(jiao)、直流母排有(you)無(wu)變形、腐(fu)蝕、氧化,母排連接處螺(luo)絲(si)(si)有(you)無(wu)松脫(tuo),各安裝固(gu)定點處堅固(gu)螺(luo)絲(si)(si)有(you)無(wu)松脫(tuo),固(gu)定用(yong)絕緣片或絕緣柱有(you)無(wu)老化開(kai)裂或變形,如有(you)應(ying)及時更換,重(zhong)新緊固(gu),對(dui)已發生變形的(de)母排須校正后重(zhong)新安裝。
(3)對(dui)(dui)線路板(ban)、母排(pai)等(deng)除塵后(hou),進(jin)行(xing)必要的(de)防腐處(chu)理(li),涂刷絕(jue)緣漆,對(dui)(dui)已出現局部放電、拉弧(hu)的(de)母排(pai)須(xu)去(qu)除其(qi)毛刺后(hou),再進(jin)行(xing)處(chu)理(li)。對(dui)(dui)已絕(jue)緣擊穿的(de)絕(jue)緣板(ban),須(xu)去(qu)除其(qi)損(sun)壞部分(fen),在其(qi)損(sun)壞附近用相應絕(jue)緣等(deng)級(ji)的(de)絕(jue)緣板(ban)對(dui)(dui)其(qi)進(jin)行(xing)隔絕(jue)處(chu)理(li),緊固并測試(shi)絕(jue)緣并認為合(he)格后(hou)方可投(tou)入使用。
(4)整流柜(ju)、逆變(bian)柜(ju)內風扇運行及轉動是否正常,停機時(shi),用手轉動,觀察軸(zhou)承有(you)無(wu)卡死或雜(za)音,必要(yao)時(shi)更換軸(zhou)承或維修。
(5)對輸入(ru)、整流及逆變、直(zhi)流輸入(ru)快熔進(jin)行全面檢查,發現燒毀及時(shi)更換。
(6)中(zhong)間(jian)直流(liu)回路中(zhong)的(de)電容(rong)器有(you)無(wu)漏(lou)液,外(wai)殼有(you)無(wu)膨脹、鼓泡(pao)或(huo)變形,安全(quan)(quan)閥是否破裂,有(you)條(tiao)件的(de)可對(dui)電容(rong)容(rong)量、漏(lou)電流(liu)、耐壓等進(jin)(jin)行(xing)測(ce)試,對(dui)不符(fu)合要(yao)求的(de)電容(rong)進(jin)(jin)行(xing)更(geng)換(huan),對(dui)新(xin)電容(rong)或(huo)長(chang)期閑置未使用的(de)電容(rong),更(geng)換(huan)前須對(dui)其進(jin)(jin)行(xing)鈍(dun)化處理。濾(lv)波電容(rong)的(de)使用周期一般為(wei)5年,對(dui)使用時間(jian)在5年以上,電容(rong)容(rong)量、漏(lou)電流(liu)、耐壓等指標明顯偏(pian)離檢測(ce)標準的(de),應酌情部分或(huo)全(quan)(quan)部更(geng)換(huan)。
(7)對整流、逆變部(bu)分的二極(ji)管、GTO用(yong)萬(wan)用(yong)表進行電氣檢測,測定(ding)其正(zheng)向(xiang)、反(fan)向(xiang)電阻值,并在事先制定(ding)好(hao)的表格內認真做(zuo)好(hao)記錄,看各極(ji)間(jian)阻值是否(fou)正(zheng)常,同一型(xing)號(hao)的器件一致性是否(fou)良好(hao),必要時進行更換(huan)。
(8)對A1、A2進(jin)(jin)線(xian)柜內的主接(jie)觸(chu)(chu)器(qi)及其(qi)它輔助接(jie)觸(chu)(chu)器(qi)進(jin)(jin)行檢查,仔細觀察各接(jie)觸(chu)(chu)器(qi)動靜觸(chu)(chu)頭有無拉(la)弧(hu)、毛刺(ci)或表面氧化、凹凸(tu)不平,發(fa)現此(ci)類(lei)問題應(ying)對其(qi)相應(ying)的動靜觸(chu)(chu)頭進(jin)(jin)行更(geng)換,確保其(qi)接(jie)觸(chu)(chu)安全(quan)可靠(kao)。
(9)仔細檢查端子排(pai)有無(wu)老化(hua)(hua)、松脫,是(shi)(shi)否(fou)(fou)存(cun)在短(duan)路隱(yin)性故障(zhang),各連(lian)接(jie)線連(lian)接(jie)是(shi)(shi)否(fou)(fou)牢固(gu),線皮有無(wu)破(po)損,各電(dian)路板接(jie)插頭接(jie)插是(shi)(shi)否(fou)(fou)牢固(gu)。進出主電(dian)源線連(lian)接(jie)是(shi)(shi)否(fou)(fou)可靠,連(lian)接(jie)處有無(wu)發熱(re)氧化(hua)(hua)等現象,接(jie)地(di)是(shi)(shi)否(fou)(fou)良好。
(10)電抗器有無異常鳴叫、振動或糊味。
另(ling)外,有條件(jian)的(de)可對濾波后的(de)直(zhi)流(liu)波形、逆變輸出(chu)波形及輸入電源諧波成分進行(xing)測定
3
備件更換變頻(pin)器由多種部(bu)件組(zu)成(cheng),其(qi)中一些(xie)部(bu)件經長(chang)期工作后其(qi)性(xing)能會逐漸降低、老化,這(zhe)也(ye)是變頻(pin)器發生故(gu)障(zhang)的主要原因,為(wei)了(le)保證設備長(chang)期的正常運轉,下列器件應定(ding)期更(geng)換:
(1)冷卻風扇
變(bian)頻(pin)器(qi)的(de)功率模塊是是發熱最(zui)嚴(yan)重的(de)器(qi)件,其連(lian)(lian)續工作所產生的(de)熱量必(bi)須要(yao)及時(shi)(shi)排(pai)出,一(yi)(yi)(yi)般風(feng)扇的(de)壽命(ming)大約為(wei)(wei)10kh~40kh。按變(bian)頻(pin)器(qi)連(lian)(lian)續運(yun)行折算為(wei)(wei)2~3年就(jiu)要(yao)更(geng)換(huan)一(yi)(yi)(yi)次風(feng)扇,直接(jie)冷卻風(feng)扇有(you)二(er)線(xian)(xian)和三線(xian)(xian)之(zhi)分,二(er)線(xian)(xian)風(feng)扇其中(zhong)一(yi)(yi)(yi)線(xian)(xian)為(wei)(wei)正極,另一(yi)(yi)(yi)線(xian)(xian)為(wei)(wei)負(fu)線(xian)(xian),更(geng)換(huan)時(shi)(shi)不要(yao)接(jie)錯;三線(xian)(xian)風(feng)扇除了正、負(fu)極外還(huan)有(you)一(yi)(yi)(yi)根(gen)檢測線(xian)(xian),更(geng)換(huan)時(shi)(shi)千萬注意,否則(ze)會引(yin)起變(bian)頻(pin)器(qi)過熱報警。交流風(feng)扇一(yi)(yi)(yi)般為(wei)(wei)220V、380V之(zhi)分,更(geng)換(huan)時(shi)(shi)電壓等級(ji)不要(yao)搞錯。
(2)濾波電容
中間直流(liu)回路濾(lv)波電(dian)(dian)容(rong)(rong)(rong):又(you)稱電(dian)(dian)解電(dian)(dian)容(rong)(rong)(rong),其主要(yao)作用就是平滑直流(liu)電(dian)(dian)壓,吸(xi)收直流(liu)中的(de)(de)(de)低頻(pin)諧波,它的(de)(de)(de)連(lian)續工(gong)作產生的(de)(de)(de)熱量(liang)(liang)加(jia)上變頻(pin)器本身產生的(de)(de)(de)熱量(liang)(liang)都會(hui)加(jia)快其電(dian)(dian)解液的(de)(de)(de)干涸,直接影響其容(rong)(rong)(rong)量(liang)(liang)的(de)(de)(de)大小。正常情況下電(dian)(dian)容(rong)(rong)(rong)的(de)(de)(de)使用壽命(ming)為5年左右。建議每年定期檢(jian)查電(dian)(dian)容(rong)(rong)(rong)容(rong)(rong)(rong)量(liang)(liang)一次,一般(ban)其容(rong)(rong)(rong)量(liang)(liang)減少(shao)20%以上應(ying)更(geng)換新的(de)(de)(de) 濾(lv)波電(dian)(dian)容(rong)(rong)(rong)器。
|
微信訂閱號
版權所有:杭州奧圣電氣(qi)有限公司????